Pallet Racking Load Calculator
Work out the beam capacity per pair and the load on each upright frame before you ask for quotes — with a live drawing of one bay.
2Estimated loads
LiveOne bay — front elevation
8 pallet positionsBays in a run share their frames. Each frame carries half of every bay it touches, so an interior frame carries one full bay and an end frame half a bay. A single stand-alone bay puts half its load on each frame.
3What to tell your supplier
“Send to suppliers” adds these numbers to the request form below. RackingZone arranges suitable pre-screened suppliers to contact you directly.
Assumptions & limitations
- Estimate only. This tool does not rate a rack. Capacities must come from the manufacturer's charts for the exact beams, frames and connectors installed — never exceed them.
- Beam capacity is per pair and uniformly distributed. Charts are normally written for the load on one front and one back beam, spread evenly. Pallets on small feet, skids or runners, or placed off-center, are not uniform loads — ask about decking or pallet supports.
- Deflection. Beam tables usually reflect the lesser of bending strength or a deflection limit of span ÷ 180 (about 0.53 in on a 96 in beam).
- Frame capacity depends on beam spacing and height. The larger the vertical gap between levels, the less a frame can carry. Moving or removing a beam level changes the rating.
- Seismic design and anchoring need engineering, as do permits in many jurisdictions. Slabs, base plates and anchors are not checked here.
- Standards. In the US, rack design follows ANSI MH16.1 (RMI); local building and fire codes apply. Post load plaques and keep the supplier's capacity documentation.
How the numbers are worked out
- Beam capacity per pair
pallets per level × heaviest pallet × (1 + allowance)- Load per bay on the frames
beam levels × beam capacity per pair— floor pallets excluded- Interior frame
½ bay + ½ bay = 1 bay- End frame
½ bay
Worked example from our guide: 2 pallets of 2,200 lb on 3 beam levels plus the floor → 4,400 lb per beam pair, 13,200 lb per bay, 13,200 lb on an interior frame, 6,600 lb on an end frame, 4,400 lb on the slab. The homepage quick calculator shows the same beam-level number (pallet weight × pallets per level) without the allowance.
Get racking sized from your loads
Your calculator results are added to the request. We'll arrange for suitable pre-screened suppliers to contact you directly with beam and frame selections from their own capacity charts.
- No obligation to buy
- You deal directly with the supplier
- Ask for capacity charts and load plaques
Request received
Thank you. We'll arrange for suitable pre-screened suppliers to contact you directly — typically within 1–2 business days.